Product Catalog
Communication cables

Signal and blocking cable SBZPu

Кабель сигнально-блокировочный СБЗПу

Application

Cable is designed for electrical communication systems and railway signaling, centralization, interlocking and automation with a rated alternating voltage of 380 V or a constant voltage of 700 V. .
The cable can be used for installation in the ground (in trenches) in an aggressive environment without significant mechanical effects on the cable, in conditions of high humidity..

Cable design

1.Conductor: copper core.
2. Insulation: PE.
3. Core wrapping: synthetic tape
4. Core filling – thixotropic gel.
5. Sheath: PE.
6. Jacket: UV stabilized PE.

Standards

ТУ У 31.3-05758730-018-2004

Main technical and mechanical characteristics

ТOperating temperature range, °C: от -50 °C до +60 °C    
Installation temperature range, °C: от -10 °C до +60 °C    
Bending radius of at least 12 cable diameters    
Minimum life service, years 25    
Conductor Diameter, mm 0,9 1,0
Conductor Electrical resistance, Ohm / km, not more than 28,8 23,3
Working capacity of conductor pairs, nF / km, no more than 100 100
Working capacity of conductors, nF / km, no more than 150 150
Insulation resistance, MOhm / km, not less than 5000 5000