Solar cables for photovoltaic systems
Photovoltaic Solar Cable H1Z2Z2-K

Description
Cables are designed for use in photovoltaic power supply systems: indoor and/or outdoor.
The special insulation has qualities of high abrasion resistance to high temperature.
Special insulation has property of flame retardant and ozone resistance.
Cables are resistant to climatic influences, UV radiation, oils and chemicals.
Construction
1. Conductor: electrolytic tinned copper, class 5 acc. to DSTU EN 60228;
2. Insulation: halogen free cross-linked polyolefin;
3. Insulation color: natural-white;
4. Outer sheath: halogen free cross-linked polyolefin;
5. Sheath color: black (red, blue - upon a request).
Standards
EN 50618
IEC 60332-1-2;
EN 60228;
EN 60811
IEC 62930.
Characteristics
| Rated voltage U0/U | 1,0/1,0 kV AC; 1,5/1,5 kV DC |
| Max. voltage | 1,2 kV AC; 1,8 kV DC (conductor/conductor, non-earthed system, circuit not under load) |
| Test voltage | 6,5kV AC; 15kV DC |
| Flame retardant acc. to | IEC 60332-1-2 |
| Halogen free acc. to | EN 50525-1, Annex B |
| Resistance to oil, acid and alkaline acc. to | EN 60811 |
| Ambient temperature in operation, °С | from -40°С to +90°С |
| Ambient temperature for installation, °С | from -25°С to +40°С |
| Max. conductor temperature, °С | 90 (Max. conductor temp 120°С and at a max. amb. temp of 90 °C is limited to 20 000 h.) |
| Max. short-circuit temperature on conductor, °С | 250 (5 sec) |
| Tensile rating in operation, N/ mm2 | 15 |
| Min bending radius | 4 diam. cable (fixed); 5 diam. cable (flexing) |
| Anticipated period of use | 25 years |
Dimensions and Weight
| No. of cores X Nominal cross section | Min outer diameter | Nominal outer diameter | Nominal weight |
| (N x mm2) | (mm) | (mm) | (kg/km) |
| 1 x 4 | 5,1 | 5,6 | 56 |
| 1 x 6 | 5,6 | 6,1 | 75 |
| 1 x 10 | 6,6 | 7,1 | 115 |
Current carrying capacity
| No. of cores X Nominal cross section | Current carrying capacity at +60°C amb. temp. acc. to the method of installation | Short Circuit current (1 sec. 90-250°C) | Electric resistant of conductor at +20°C | ||
| Single cable free in air | Single cable on a surface | Two loaded cables touching, on a surface | |||
| (N x mm2) | (A) | (A) | (A) | (kA) | (Ω/km) |
| 1 x 4 | 55 | 52 | 44 | 0,57 | 5,09 |
| 1 x 6 | 70 | 67 | 57 | 0,86 | 3,39 |
| 1 x 10 | 98 | 93 | 79 | 1,43 | 1,95 |
Current rating conversion factors for deviating temperatures
| Ambient temperature | Conversion factor |
| (°C) | |
| Up to 60 | 1.00 |
| 70 | 0.92 |
| 80 | 0.84 |
| 90 | 0.75 |