For heating roofs and gutters (anti-icing)
Single core heating cable 23 W/m with copper braid shield
Application
For outdoor surfaces heating (roofs, gutters, open areas, roads, sidewalks) in conditions of low mechanical stress (class M1). Operating temperature is no more than 90° С. Specific power, max. 23 W/m.
Supplied in the form of ready-to-use sections from 15 to 194 meters long, with a power from 0.32 to 4.45 kW (230 V). Sections have two attached power cables of different cross-section size (acc. to length/loads) with hermetic connection class IPX7.
Cable design
1) Conductor: copper core
2) Inner insulation: elastomer
3) Outer insulation: PVC compound
4) Shield material: copper braid
5) Sheath: PVC compound
Standards
IEC 800
Marking
HEATING CABLE WOKS 23 ODESKABEL MAX 90 °C
Main technical and mechanical characteristics
Conductor diameter, mm: | 5,6 |
Estimated cable weight, kg/km: | 61.2 |
Operating temperature range: | from -40° С to +50° С |
Installation temperature range: | not lower than -5° С |
Bending radius: | of at least 6 cable diameters |
Tension resistance: | no more than 120 N |
Deformation resistance, for cables of M1 class: | no more than 600 N |
Shield electrical resistance: | no more than 34,5 Ohm |
Insulation electrical resistance (60s/1000V): | not less than 1 MOhm |