RF cables RK 75-2-13
RK 75-2-13
Application
The cables are intended for inner installation in security alarm and surveillance systems, satellite television systems, for transmitting a radio frequency signal from a receiving antenna to a television, as switching microwave devices in the frequency range from 5 to 3000 MHz.
Cable design
1. Conductor: copper wire 0.36 mm (7*0.12mm)
2. Insulation: PE
3. Shield Material: copper braid
4. Sheath: UV-stabilized PE
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C ... +60 °C;
- Operating Temp Range: -50 °C ... +60 °C.
Standards
Main technical and mechanical characteristics
Electrical parameters at 20°C | Frequency, kHz | Value |
Test voltage for 1 min, kV- between the inner and outer conductor | 0,05 | 1,0 |
Electric resistance of internal conductor, Ohm / km, no more | D.C. | 222 |
Impedance, ohm | from 5 000 to 3 000 000 | 75 ± 3 |
Working capacity, pF / m | from 0,8 to 1,0 | 54,3±6 |
Attenuation coefficient, nom., DB / 100m | 200 000 1 000 000 |
30,55 68,66 |
Nomenclature and mass-dimensional characteristics
Cable brand | Outside diameter, mm | Weight, kg/km |
RK 75-2-13 | 3,4 | 17,5 |