Product Catalog
Cables for video surveillance KSV-1

KSV-1 + 2 * 0.22 (P), KSV-1 + 2 * 0.50 (P)

Кабели для видеонаблюдения КСВ-1+2*0,22(П), КСВ-1+2*0,50(П)

Application

Cables for indoor and outdoor installation (marked "P") in alarm systems and video surveillance.
Operation at frequencies from 5 MHz to 1000 MHz. The cores of remote power supply (DP) are used to connect power to remote devices (cameras, splitters, etc.) and / or to transmit control signals.

Cable design

1. Radio frequency cable:
1.1. Conductor: copper 0.36 mm
1.2. Insulation: FHDPE
1.3. Shield Material: copper braid
1.4. Sheath: PVC
2. Remote power supply cores.
2.1. Copper wire. 0.22 mm2 or 0.50 mm2
2.2. Insulation: PVC
3. General insulation
3.1. KSV-1 + 2 * 0.22 (KSV-1 + 2 * 0.50) - PVC
3.2. KSV-1 + 2 * 0.22P (KSV-1 + 2 * 0.50P) - UV-stabilized PE

Installation and operation conditions

Temp Rating KSV-1 + 2 * 0.22 (KSV-1 + 2 * 0.50):
- Installation Temp Rating: -10 °C ... +60 °C;
- Operating Temp Range: -20 °C ... +60 °C.
Min Bend Radius: ≥ 10 
Temp Rating KSV-1 + 2 * 0.22P (KSV-1 + 2 * 0.50P):
- Installation Temp Rating: -10 °C ... +60 °C;
- Operating Temp Range: -50 °C ... +60 °C.
Min Bend Radius: ≥ 10 

Standards

Main technical and mechanical characteristics

Electrical parameter at 20 ° C Frequency, kHz Value
Test voltage for 1 min, kV
Between the inner conductor and the braid; between supply cores
D.C.
0,05
0,8
0,6
Electrical resistance lived DP, Ohm/km, no more than
- for supply cores with a cross section of 0.22 mm2
- for supply cores with a section of 0.50 mm2
D.C.
90
45
Radio frequency cable wave impedance, Ohms 5000 - 1 000 000 75

Nomenclature and mass-dimensional characteristics

Cable brand Outside diameter, mm Weight, kg/km
KSV-1+2*0,22 5,6 33,1
KSV-1+2*0,22P 5,6 28,6
KSV-1+2*0,50 5,9 40,8
KSV-1+2*0,50P 5,9 36,0