Communication cables
Cable signaling and blocking SBPu
Application
The cable is designed for electrical communication systems and railway signaling, centralization, interlocking and automation with a rated alternating voltage of 380 V or a constant voltage of 700 V.
The cable can be used for installation in the ground (in trenches) in an aggressive environment without significant mechanical effects on the cable.
Cable design
1. Conductor: copper core.
2. Insulation: PE.
3. Wrapping: synthetic tape.
4. Sheath: PE.
5. Jacket: UV Stabilazed PE.
Standards
ТУ У 31.3-05758730-018-2004
Main technical and mechanical characteristics
Operating temperature range, °C: от -50 °C до +60 °C | ||
Installation temperature range, °C: от-15 °C до +60 °C | ||
Bending radius of at least 12 cable diameters | ||
Conductor Diameter, mm. | 0,9 | 1,0 |
Conductor Electrical resistance, Ohm / km, not more than | 28,8 | 23,3 |
Working capacity of conductor pairs, nF / km, no more than | 100 | 100 |
Working capacity of conductors, nF / km, no more than | 150 | 150 |
Insulation resistance, MOhm / km, not less than | 5000 | 5000 |