Cables for the industrial interface armored KIF-VKG
KIF-VKG Nx2x0.6
Application
Cables are designed for high-speed data transfer in accordance with ISO / IEC 8482, EIA RS-485 (TIA / EIA-485-A). For outdoor installation in telephone conduits, in sewers, mines, along the walls of buildings in case of danger of damage by rodents. Allowed for installation and operating on the outer walls of buildings while providing protection from moisture.
Cable design
1. Conductor: copper wire 0.60 mm
2. Insulation: FHDPE
3. Shield Material: aluminum foil + tinned copper braid
4. Copper tinned contact wire
5. Sheath: PVC
6. Braid: galvanized steel wire
Installation and operation conditions
Temp Rating:
- installation Temp Rating: -10 °C ... +60 °C;
- operating Temp Range: -20 °C ... +60 °C.
Min Bend Radius: ≥ 10
Minor Axis: ≤ 450 N.
Standards
ISO IEC 8482, EIA RS-485 (ТIA/EIA-485-A)
Main technical and mechanical characteristics
Electrical parameter at 20 ° C | Frequency, kHz | Value |
Test voltage for 1 min, kV - between all cores and the screen: - between the veins of the pair: |
D.C. 0,05 D.C. 0,05 |
0,7 0,5 1,4 1,0 |
Conductor electrical resistance, Ohm / km, no more than | D.C. | 100 |
Electrical insulation resistance,per 1 km, t. 20 C, MΩ, not less | D.C. | 150 |
Conductor pair electric capacitance, pF / m | from 0,8 to 1,0 | 40±4 |
Average wave impedance, Ohm | 1000 | 120 ± 12 |
Аttenuation, no more, dB / 100m | 1000 | 2,1 |
Nomenclature and mass-dimensional characteristics
Cable brand | Outside diameter, mm | Weight, kg/km |
KIF-VKG 1х2х0,6 | 6,9 | 92,5 |
KIF-VKG 1.5х2х0,6 | 7,7 | 115,1 |
KIF-VKG 2х2х0,6 | 8,2 | 123,5 |
KIF-VKG 3х2х0,6 | 12,1 | 179,6 |
KIF-VKG 4х2х0,6 | 12,8 | 196,5 |
KIF-VKG 5х2х0,6 | 13,5 | 214,0 |
KIF-VKG 6х2х0,6 | 16,0 | 250,9 |