Floor heating cables
Heating cable 18 W/m with solid aluminum shield
Application
For room heating (by installing under the floor covering) in conditions of low mechanical stress (class M1). Operating temperature is no more than 90° С. Specific power, max. 18 W/m.
Supplied in the form of ready-to-use sections from 6 to 162 meters long, with a power from 100 to 2,92 kW (230 V). Sections have an attached power cable with hermetic connection class IPX7.
Cable design
1) Conductor: copper core
2) Insulation: elastomer
3) Copper tinned contact wire
4) Shield material: aluminum foil
5)Sheath: PVC compound
Standards
ТIEC 800
Marking
HEATING CABLE WOKS 18 ODESKABEL MAX 90 °C
Main technical and mechanical characteristics
Conductor diameter, mm: | 4 |
Estimated cable weight, kg/km: | 24.2 |
Operating temperature range: | from -40° С to +50° С |
Installation temperature range: | not lower than -5° С |
Bending radius: | of at least 6 cable diameters |
Tension resistance: | no more than 120 N |
Deformation resistance, for cables of M1 class: | no more than 600 N |
Shield electrical resistance: | no more than |
Insulation electrical resistance (60s/1000V): | not less than 1 MOhm |