Communication cables
Signal and blocking cable SBVG
Application
The cable is designed for railway circuits, electrical installations of signaling, centralization, blocking, fire alarm, telegraph and automation with a rated alternating voltage of 380 V or a constant voltage of 700 V.
Installation in rooms, in dry channels and tunnels, in an aggressive environments in the absence of mechanical stress on the cable.
Cable design
1. Conductor: copper core.
2. Insulation: PE.
3. Core wrapping : synthetic tape.
4. Jacket: UV stabilized PE.
Design versions:
Jacket: LSZH
Standards
ТУ У 31.3-05758730-018-2004
Main technical and mechanical characteristics
Operating temperature range, °C: от -40 °C до +60 °C | ||
Installation temperature range, °C: от-10 °C до +60 °C | ||
Bending radius of at least 12 cable diameters | ||
Minimum life service, years 25 | ||
Conductor Diameter, mm | 0,9 | 1,0 |
Conductor Electrical resistance, Ohm / km, not more than | 28,8 | 23,3 |
Working capacity of conductor pairs, nF / km, no more than | 100 | 100 |
Working capacity of conductors, nF / km, no more than | 150 | 150 |
Insulation resistance, MOhm / km, not less than | 5000 | 5000 |