Cables for the industrial interface KIF-Vng (A) -LS (KIPvEng (A) -HF)
KIF-ng (A) -HF (KIPvEng (A) -HF) Nx2x0.78
Application
Cables are designed for high-speed data transfer in acc. ISO / IEC 8482, EIA RS-485 (TIA / EIA-485-A). Used for stationary installation inside buildings, stations, structures, equipment. Allowed for installation and operating on the outer walls of buildings while providing protection from moisture.
Cable design
1. Conductor: copper wire 0.78 mm
2. Insulation: FHDPE
4. Shield Material: aluminum foil + tinned copper braid
5. Copper tinned contact wire
6. Sheath: low smoking, halogen-free, flame retardant compound
Installation and operation conditions
Temp Rating:
- Installation Temp Rating: -10 °C ... +60 °C;
- Operating Temp Range: -20 °C ... +60 °C.
Min Bend Radius: ≥ 10
Minor Axis: ≤ 120 N.
Standards
ISO IEC 8482, EIA RS-485 (ТIA/EIA-485-A)
Main technical and mechanical characteristics
Electrical parameter at 20 ° C | Frequency, kHz | Value |
Test voltage for 1 min, kV - between all cores and the screen: - between the veins of the pair: |
D.C. 0,05 D.C. 0,05 |
0,7 0,5 1,4 1,0 |
Conductor electrical resistance, Ohm / km, no more than | D.C. | 59 |
Electrical insulation resistance,per 1 km, t. 20 C, MΩ, not less | D.C. | 150 |
Conductor pair electric capacitance, pF / m | from 0,8 of 1,0 | 40±4 |
Average wave impedance, Ohm | 1000 | 120 ± 12 |
Аttenuation, no more, dB / 100m | 1000 | 1,65 |
Nomenclature and mass-dimensional characteristics
Cable brand | Outside diameter, mm | Weight, kg/km |
KIF-ng(А)-HF 1х2х0,78 | 7,4 | 66 |
KIF-ng(А)-HF 1,5х2х0,78 | 7,8 | 69 |
KIF-ng(А)-HF 2х2х0,78 | 8,8 | 86 |
KIF-ng(А)-HF 3х2х0,78 | 9,4 | 95 |
KIF-ng(А)-HF 4х2х0,78 | 9,4 | 106 |
KIF-ng(А)-HF 5х2х0,78 | 10,3 | 120 |
KIF-ng(А)-HF 6х2х0,78 | 11,2 | 135 |