KIF-PBP (KIPvPBP) Nx2x0.78
Application
Cables are designed for high-speed data transfer in acc. ISO / IEC 8482, EIA RS-485 (TIA / EIA-485-A). For outdoor installation in the ground (if significant mechanical impacts on the cable are absent), telephone sewage, in collectors, mines, along the walls of buildings in case of danger of damage by rodents, in conditions of high humidity.
Cable design
1. Conductor: copper wire 0.78 mm
2. Insulation: FHDPE.
3. Inner shield Material: aluminum foil + tinned copper braid
4. Copper tinned contact wire
5. Inner sheath: PVC
6. Armouring - corrugated laminated steel tape
7. Outer sheath: PE
Installation and operation conditions
Temp Rating:
- installation Temp Rating: -10 °C ... +60 °C;
- operating Temp Range: -50 °C ... +60 °C.
Min Bend Radius: ≥ 20
Minor Axis: ≤ 450 N.
Standards
ISO IEC 8482, EIA RS-485 (ТIA/EIA-485-A)
Main technical and mechanical characteristics
Electrical parameter at 20 ° C | Frequency, kHz | Value |
Test voltage for 1 min, kV | ||
- between all cores and the screen: | D.C. | 0,7 |
0,05 | 0,5 | |
- between the veins of the pair: | D.C. | 1,4 |
0,05 | 1,0 | |
Conductor electrical resistance, Ohm / km, no more than | D.C. | 59 |
Electrical insulation resistance,per 1 km, t. 20 C, MΩ, not less | D.C. | 150 |
Conductor pair electric capacitance, pF / m | from 0,8 to 1,0 | 40±4 |
Average wave impedance, Ohm | 1000 | 120 ± 12 |
Аttenuation, no more, dB / 100m | 1000 | 1,65 |
Nomenclature and mass-dimensional characteristics
Cable brand | Outside diameter, mm | Weight, kg/km |
KIF-PBP 1х2х0,78 | 11,0 | 134 |
KIF-PBP 1,5х2х0,78 | 11,0 | 136 |
KIF-PBP 2х2х0,78 | 12,4 | 164 |
KIF-PBP 3х2х0,78 | 13,0 | 181 |
KIF-PBP 4х2х0,78 | 13,0 | 184 |
KIF-PBP 5х2х0,78 | 14,0 | 215 |
KIF-PBP 6х2х0,78 | 14,8 | 234 |