Communication cables
Telephone cable TPPep (double paired)
Application
Designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC. The cable can be used for installation in telephone sewers, in sewers, mines, along the walls of buildings and suspension on overhead communication lines.
Cable design
1. Conductor: copper core.
2. Insulation: PE.
3. Core wrapping: synthetic tape.
4. Copper tinned contact wire.
5. Shield material: aluminum foil.
6. Jacket: PVC.
Standards
ТУ У 05758730-040-2006
МЭК 60708-1
МЭК 60189-1
Main technical and mechanical characteristics
Operating temperature range, °C: от -50 °C до +60 °C | |||||
Installation temperature range, °C: от-15 °C до +60 °C | |||||
Bending radius of at least 10 cable diameters | |||||
Diameter of conductors, mm: | 0,40 | 0,50 | 0,60 | 0,80 | 0,90 |
Conductor electrical resistance D.C, Ohm/km, no more than: | 148 | 96 | 65 | 36,6 | 28,4 |
Capacity (0.8 to 1 kHz), nF/km: | 50 | 50 | 50 | 50 | 50 |
Insulation elecrical resistance, MOhm/km, not less than | 5000 | 5000 | 5000 | 5000 | 5000 |
Коэффициент емкостной связи k1, пересчитанный на 300 м длины, пФ, не более | 600 | 600 | 600 | 600 | 600 |
Коэффициенты емкостной связи k9-k12, пересчитанные на 300 м длины, пФ, не более | 300 | 300 | 300 | 300 | 300 |