Category 6 cables
U/UTP Cat.6 4Pr Indoor
Apllications
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Token Ring 16/100 Mbit/s, Fast Ethernet (100BASE-TX), 1000BASE-T, 2.5GBASE-T, 5GBASE-T, PoE, PoE+, 4PPoE
Design
1) Conductor: Solid annealed copper
2) Insulation: HDPE
3) Pair: two conductors twisted
4) Cross-web: HDPE, 2,6x2,6 mm
5) Jacket: LS0H, nominal thickness 0,5 mm; PVC, nominal thickness 0,5 mm
Standards
Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568.2-D
Cable: IEC 61156-5, EN 50288-6-1
Fire safety:
LS0H jacket: EN 60332-1-2
CPR class: Eca
Mechanical characteristics
Temperature range:
- During installation -10 °C ... +60 °C
- After installation -20 °C ... +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter | Unit | Value |
Capacitance | pF/m | ≤ 56 |
Electrical resistance tfzh to direct current: | Оhm/km | |
- with a diameter of TPG 0.52 mm | ≤ 87 | |
- with a diameter of TPG 0,54 mm | ≤ 82 | |
- with a diameter of TPG 0,57 mm | ≤ 75 | |
Resistance unbalance | % | 2 |
Insulation resistance | GOhm/km | ≥ 5 |
Signal propagation velocity | % | 68 |
Characteristic impedance in the frequency range of: | Ohm | |
1-100 MHz | 100 +/-15 | |
100-250 MHz | 100 +/-22 | |
Test voltage between cores, (DC, 2 s) | kV | 2,5 |
Frequency, MHz | 1 | 4 | 10 | 16 | 20 | 31,25 | 62,5 | 100 | 250 |
Attenuation, dB, max | 2,1 | 3,8 | 6 | 7,6 | 8,5 | 10,7 | 15,5 | 19,9 | 33 |
NEXT, dB, min | 75,3 | 66,3 | 60,3 | 57,2 | 55,8 | 52,9 | 48,4 | 45,3 | 39,3 |
PS NEXT, dB, min | 72,3 | 63,3 | 57,3 | 54,2 | 52,8 | 49,9 | 45,4 | 42,3 | 36,3 |
ELFEXT, dB, min | 68 | 56 | 48 | 43,9 | 42 | 38,1 | 32,1 | 28 | 20 |
PS ELFEXT, dB, min | 65 | 53 | 45 | 40,9 | 39 | 35,1 | 29,1 | 25 | 17 |
RL, dB, min | 20 | 23 | 25 | 25 | 25 | 23,6 | 21,5 | 20,1 | 17,3 |
Order information
P/N | Cable name | Jacket | Diameter of TPG, mm | Conductor diameter mm | Diameter / cable size, mm |
Standard packing |
Estimated weight, kg/km |
7931167 | KPV-VP (250) 4*2*0,57 (U/UTP-cat.6) | PVC | 0,57 | 1,09 | 6,0 | box 305 m | 40,1 |
49218 | KPVong-HF-VP (250) 4*2*0,57 (U/UTP-cat.6 LSOH) | LSZH | 0,57 | 1,09 | 6,0 | box 305 m | 39,5 |
49210 | KPVng-HF-VP (250) 4*2*0,57 (U/UTP-cat.6 LSFROH) | LSZFRZH | 0,57 | 1,09 | 6,0 | box 305 m | 40,5 |
7931193 | KPV-VP (250) 4*2*0,54 (U/UTP-cat.6) | PVC | 0,54 | 0,94 | 5,6 | box 305 m | 35,7 |
49213 | KPVong-HF-VP (250) 4*2*0,54 (U/UTP-cat.6 LSOH) | LSZH | 0,54 | 0,94 | 5,6 | box 305 m | 35,0 |
7931189 | KPVng-HF-VP (250) 4*2*0,54 (U/UTP-cat.6 LSFROH) | LSZFRZH | 0,54 | 0,94 | 5,6 | box 305 m | 37,6 |
7931099 | KPV-VP (250) 4*2*0,52 (U/UTP-cat.6) | PVC | 0,525 | 0,91 | 5,4 | box 305 m | 35,8 |
7931154 | KPVong-HF-VP (250) 4*2*0,52 (U/UTP-cat.6 LSOH) | LSZH | 0,525 | 0,91 | 5,4 | box 305 m | 33,7 |
7931199 | KPVng-HF-VP (250) 4*2*0,52 (U/UTP-cat.6 LSFROH) | LSZFRZH | 0,525 | 0,91 | 5,4 | box 305 m | 34,7 |