F-UTP Cat.6 4Pr Indoor
Application
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T
Cable design
1. Conductor: soft copper wire
2. Insulation: PE
3. Pair: two conductors twisted together:
- Pair 1: white-blue / blue
- Pair 2: white-orange / orange
- Pair 3: white-green / green
- Pair 4: white – brown / brown
4. Cross-web (PE or LSFRZH)
5. Core wrapping
6. Core shield: aluminum polymer foil (metal inside)
7. Cooper tinned contact wire Ø 0,4 mm
8. Sheath: PVC, LSZH or LSFRZH
Mechanical characteristics
Тemperature range:
- During installation: -10 °C...+60 °C
- After installation: -20 °C...+60 °C
Bending radius: ≥ 10 cable diameters
Tensile stress: ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 0С
Parameter | Ед. изм. | Значение |
Capacitance, no more | pF/m | 56 |
Direct current resistance: | Оhm/km | |
- Conductor diameter 0,54 mm, not more than | 83 | |
- Conductor diameter 0,57 mm, not more than | 88 | |
Resistance unbalance, no more | % | 2 |
Insulation resistance, no less | GOhm/km | 5 |
Nominal signal propagation speed | % | 68 |
Characteristic impedance in the frequency range of | Ohm | |
-1-100 MHz | 100 +/-15 | |
-100-250 MHz | 100 +/-22 | |
Test voltage between cores, (DC, 2 s) | kV | 2,5 |
Signal transmission characteristics at 20 0 C
Frequency, MHz | 1 | 4 | 10 | 16 | 20 | 31,25 | 62,5 | 100 | 250 |
Attenuation, dB/100 m, max | 2,1 | 3,8 | 6 | 7,6 | 8,5 | 10,7 | 15,5 | 19,9 | 33 |
NEXТ, dB, min | 75,3 | 66,3 | 60,3 | 57,2 | 55,8 | 52,9 | 48,4 | 45,3 | 39,3 |
PS NEXТ, dB, min | 72,3 | 63,3 | 57,3 | 54,2 | 52,8 | 49,9 | 45,4 | 42,3 | 36,3 |
ELFEXТ, dB, min | 68 | 56 | 48 | 43,9 | 42 | 38,1 | 32,1 | 28 | 20 |
PS ELFEXТ, dB, min | 65 | 53 | 45 | 40,9 | 39 | 35,1 | 29,1 | 25 | 17 |
Return Loss, dB, min | 20 | 23 | 25 | 25 | 25 | 23,6 | 21,5 | 20,1 | 17,3 |
ORDER INFORMATION
P/N | Cable name | Jacket | Conductor Ø, mm | Insulated conductor Ø, mm | Outer cable Ø, mm | Packing | Weight, kg/km |
49342 | КПВЭ-ВП (250) 4*2*0,57 (F/UTP-cat.6) | ПВХ | 0,57 | 1,11 | 6,9 | Plywood reel 305/500/1000 м | 49,5 |
7932024 | КПВонг-HFЭ-ВП (250) 4*2*0,57 (F/UTP-cat.6 LSOH) | LSZH | 0,57 | 1,11 | 6,9 | Plywood reel 305/500/1000 м | 49,9 |
7932106 | КПВнг-HFЭ-ВП (250) 4*2*0,57 (F/UTP-cat.6 LSFROH) | LSZFRZH | 0,57 | 1,11 | 6,9 | Plywood reel 305/500/1000 м | 55,7 |
7932020 | КПВЭ-ВП (250) 4*2*0,54 (F/UTP-cat.6) | ПВХ | 0,54 | 1,03 | 6,7 | Plywood reel 305/500/1000 м | 46,1 |
7932025 | КПВонг-HFЭ-ВП (250) 4*2*0,54 (F/UTP-cat.6 LSOH) | LSZH | 0,54 | 1,03 | 6,7 | Plywood reel 305/500/1000 м | 46,5 |
7932109 | КПВнг-HFЭ-ВП (250) 4*2*0,54 (F/UTP-cat.6 LSFROH) | LSZFRZH | 0,54 | 1,03 | 6,7 | Plywood reel 305/500/1000 м | 49,2 |