Product Catalog
Category 7 cables

F/FTP Cat.7 4Pr Outdoor

F/FTP Cat.7 4Pr Outdoor

APPLICATION

PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T

DESIGN

1) Conductor: soft copper wire Ø 0,56 mm

2) Insulation: skin-foam-skin HDPE, Ø 1,35 mm

3) Pair: two conductors twisted

4) Pair shielding: Individual Al/Pet foil (metal outside)

5) Copper tinned contact wire Ø 0,4 mm

6) Core wrapping, overlapping minus 40%

7) Core shield: Aluminum/Polyester foil

8) Jacket: PVC or LSZH, thickness 0,5 mm, nominal cable Ø 6,9 mm

СOMPLIANCE WITH THE REQUIREMENTS

Cabling: ISO/IEC 11801-1, EN 50173-1, ANSI/TIA-568-C.2

Cable: IEC 61156-5, EN 50288-6-1

Fire safety:

- Flame propagation (PVC and LSZH) – IEC 60332-1-2

- Zero halogen, no corrosive gases (LSZH) – IEC 60754-2

- Smoke density (LSZH) – IEC 61034-2

MECHANICAL CHARACTERISTICS

Temperature range:

- During installation -10 °C ... +60 °C

- After installation -20 °C ... +60 °C

Bending radius:

- During installation ≥ 8 cable diameters

- After installation ≥ 4 cable diameters

Tensile stress ≤ 85 N

ELECTRICAL CHARACTERISTICS AT 20 °C

Parameter Unit Value
Capacitance pF/m ≤ 56
Direct current resistance Оhm/km ≤ 75
Resistance unbalance % 2
Insulation resistance GOhm/km ≥ 5
Signal propagation velocity % 80

Characteristic impedance in the frequency range of:

Ohm  
1-100 MHz   100 +/-15
100-250 MHz   100 +/-22
250-600 MHz   100 +/-25
Test voltage between cores, (DC, 2 s) kV 2,5

Frequency, MHz 1 4 10 16 20 31,25 62,5 100 250 500 600
Attenuation, dB, max 2 3,7 5,9 7,4 8,3 10,4 14,9 19 31 45,3 50,1
NEXT, dB, min 78 78 78 78 78 78 75,5 72,4 66,4 61,9 60,7
PS NEXT, dB, min 75 75 75 75 75 75 72,5 69,4 63,4 58,9 57,7
ELFEXT, dB, min 78 78 75,3 71,2 69,3 65,4 59,4 55,3 47,3 41,3 39,7
PS ELFEXT, dB, min 75 75 72,3 68,2 66,3 62,4 56,4 52,3 44,3 38,3 36,7
RL, dB, min 20 23 25 25 25 23,6 21,5 20,1 17,3 17,3 17,3

ORDER INFORMATION

P/N Cable name Jacket Diameter of TPG, mm Conductor diameter mm Diameter / cable size, mm Standard packing Weight, kg/km
7935066 KPpVE-VPE (600) 4*2*0,56 (F/FTP-cat.7) PE 0,565 1,35 7,1 Plywood reel 305/500/1000 m 47,7
No records found.

MOD_BARCODE_MOD_TITLE

MOD_BARCODE_BUHTA

MOD_BARCODE_BARABAN